NewsNavigation
New product——SHT-2010 touch screen temperature and humidity controller

Product Name: Temperature and Humidity Controller Product Model: SHT2010

Power supply voltage: AC 110 ~ 230V Power supply frequency: 50 / 60Hz

Temperature measurement range: -20 ~ 60 ℃ Humidity measurement range: 0% ~ 100% RH

Temperature measurement accuracy: 0.3 ℃ Humidity measurement accuracy: 3%

Output control: relay output Output power: MAX 10A

Setting method 1: Start value <stop value (the program automatically determines the working mode is heating / humidifying mode).

Setting method 2: Start value> Stop value (the program automatically determines that the working mode is cooling / dehumidifying mode).

Setting essentials 3: In the setting mode, pressing the button for 5 seconds without operation will automatically return to the normal display state.

Heating / cooling mode setting:

Setting (starting temperature): Press and hold the ▲ button, the starting temperature flashes, and set the starting temperature value with the ▲ ▼ keys.

Setting (stop temperature): Press and hold the ▼ button to stop the temperature flashing, and set the stop temperature value with the ▲ ▼ keys.

 

Heating use case: control the water heater, stop heating at 65 ℃, and start heating again when the temperature drops to 50 ℃;

Step 1: Long press the ▲ button for 3 seconds to start the temperature flashing, and set the startup temperature to 50 ° C with the ▲ ▼ keys;

Step 2: Press and hold the ▼ button for 3 seconds to stop the temperature flashing. Use the ▲ ▼ keys to set the stop temperature to 65 ° C. The setting is complete.

Note: heating mode, start temperature <stop temperature;

Refrigeration use case: for use in the farm, the fan ventilation stops at 26 ℃, and the temperature rises to 30 ℃ to start ventilation again;

  Step 1: Press and hold the ▲ button for 3 seconds to start the temperature flashing, and set the startup temperature to 30 ° C with the ▲ ▼ keys;

  Step 2: Press and hold the ▼ button for 3 seconds to stop the temperature flashing. Use the ▲ ▼ keys to set the stop temperature to 26 ° C. The setting is complete.

Note: In cooling mode, start temperature> stop temperature;

 

Humidification / dehumidification mode setting:

Setting (Starting Humidity): Long press the △ key, the starting humidity value blinks, and set the starting humidity value by the △ ▽ key. Setting [Stop Humidity]: Long press the △ key, stopping the humidity value blinking, setting the stop humidity value.

 

Humidification use case: fresh supermarket humidification, control humidifier 50% RH start humidification, humidification to 80% RH stop humidification;

  Step 1: Press and hold the △ key for 3 seconds to start the humidity value blinking, and set the startup humidity to 50% RH with the △ ▽ key;

  Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value from flashing. Set the stop humidity to 80% RH with the △ ▽ key. The setting is complete.

  Note: Humidification work mode, start humidity <stop humidity;

Dehumidification use case: workshop controlled exhaust air dehumidification system, dehumidification starts at 70% RH, and dehumidification stops at 40% RH;

  Step 1: Press and hold the △ key for 3 seconds to start the humidity value blinking, and set the startup humidity to 40% RH with the △ ▽ key;

  Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value from flashing. Set the stop humidity to 70% RH with the △ ▽ key, and the setting is complete.

  Note: Dehumidification working mode, start humidity> stop humidity;

 

Temperature correction:

First press the ▲ key, then press the ▼ key for 3 seconds to start the temperature digital flashing, and set the start temperature correction value with the ▲ ▼ key;

 

Humidity correction:

First press the ▽ key, then press the △ key for 3 seconds to start the humidity digital flashing, and set the start humidity correction value with the △ ▽ key;

 

Restore factory settings: